Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters

Database
Language
Document Type
Year range
1.
J Virol Methods ; 299: 114352, 2022 01.
Article in English | MEDLINE | ID: covidwho-1500117

ABSTRACT

A number of RT-qPCR assays for the detection of SARS-CoV-2 have been published and are listed by the WHO as recommended assays. Furthermore, numerous commercial assays with undisclosed primer and probe sequences are on the market. As the SARS-CoV-2 pandemic progresses, the virus accrues mutations, which in some cases - as seen with the B.1.1.7 variant - can outperform and push back other strains of SARS-CoV-2. If mutations occur in primer or probe binding sites, this can impact RT-qPCR results and impede SARS-CoV-2 diagnostics. Here we tested the effect of primer mismatches on RT-qPCR performance in vitro using synthetic mismatch in vitro transcripts. The effects of the mismatches ranged from a shift in ct values from -0.13 to +7.61. Crucially, we found that a mismatch in the forward primer has a more detrimental effect for PCR performance than a mismatch in the reverse primer. Furthermore, we compared the performance of the original Charité RdRP primer set, which has several ambiguities, with a primer version without ambiguities and found that without ambiguities the ct values are ca. 3 ct lower. Finally, we investigated the shift in ct values observed with the Seegene Allplex kit with the B.1.1.7 SARS-CoV-2 variant and found a three-nucleotide mismatch in the forward primer of the N target.


Subject(s)
COVID-19 , SARS-CoV-2 , Binding Sites , Humans , Mutation , RNA, Viral/genetics , Sensitivity and Specificity
2.
J Virol Methods ; 290: 114083, 2021 04.
Article in English | MEDLINE | ID: covidwho-1051816

ABSTRACT

In the current pandemic of SARS-CoV-2, rapid identification of infected individuals is crucial for management and control of the outbreak. However, transport of samples, sample processing and RT-qPCR analysis in laboratories are time-consuming. Here we present a prototype of a novel nucleic acid-based test format - pulse controlled amplification - that allows detection of SARS-CoV-2 directly from up to eight swab samples simultaneously without the need for RNA extraction within 25 min with a sensitivity of 100 % for samples with a viral load of ≥ 1.6 × 10e3 copies/µl This new principle might pave the way to rapid and sensitive point of care testing.


Subject(s)
COVID-19 Nucleic Acid Testing/methods , COVID-19/diagnosis , Nucleic Acid Amplification Techniques/methods , SARS-CoV-2/isolation & purification , COVID-19 Nucleic Acid Testing/standards , Humans , Nucleic Acid Amplification Techniques/standards , Point-of-Care Testing , RNA, Viral/genetics , SARS-CoV-2/genetics , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL